A message from the YachtProtect device will be send automatically every 6 hours (status update). Also a message will be send when an alarm level exceeds or when a warning level exceeds (configurable by user) or when the Press push button on YachtProtect device Send message is pressed
A message from the YachtProtect device will be send automatically when the battery voltage becomes under or above the alarm level. Also a message can be send when the battery voltage becomes under or above the warning level (configurable by user).
A message from the YachtProtect device will be send automatically when the temperature becomes under or above the alarm level. Also a message can be send when the temperature becomes under or above the warning level (configurable by user).
A message from the YachtProtect device will be send automatically when the smoke/gas level becomes under or above the alarm level. Also a message can be send when the smoke/gas level becomes under or above the warning level (configurable by user).
A message from the YachtProtect device will be send automatically when the auxiliary contact is activated.
A message from the YachtProtect device will be send automatically when the liquid sensor becomes on the alarm level. Also a message can be send when the liquid sensor becomes on the warning level (configurable by user).
Messages Dashboard Smartphone E-mail
A message will be send:      
Alarm level exceeds (see below) – will be send immediately
Warning level exceeds (see below) – will be send immediately Configurable Configurable
Every 6 hours a status update message    
Press push button on YachtProtect device Send message
       
Battery voltage:      
Low battery voltage - warning level Configurable Configurable
Low battery voltage - alarm level
High battery voltage - warning level Configurable Configurable
High battery voltage - alarm level
       
Temperature:      
Low temperature - warning level Configurable Configurable
Low temperature - alarm level
High temperature - warning level Configurable Configurable
High temperature - alarm level
       
Smoke/Gas detection:      
Warning level Configurable Configurable
Alarm level
       
Auxiliary input:      
NC contact opened
       
Liquid sensors:      
Warning level Configurable Configurable
Alarm level
LED indications on YachtProtect device LED color
Power supply (battery voltage)  
No battery voltage OFF
Low battery voltage - warning level Blue
Low battery voltage - alarm level Red
Nominal battery voltage Green
High battery voltage - warning level Blue
High battery voltage - alarm level Red
   
Auxiliary input  
NC contact closed Green
NC contact open Red
   
Liquid sensors  
Liquid sensor not connected or cable fault OFF
Liquid sensor connected, no liquid warning or liquid alarm Green
Liquid sensor connected, liquid warning Blue
Liquid sensor connected, liquid alarm Red
   
Communication  
No communication OFF
Communication start up active Green
Communication OK Blue
Communication fault (low signal) Red
Parameter Default value Configurable
Warning level Alarm level Warning level Alarm level
Battery voltage        
Low battery voltage (battery voltage +12 Vdc) 11.0 Vdc 10.0 Vdc 10.5 - 12.0 Vdc 8.5 - 10.5 Vdc
High battery voltage (battery voltage +12 Vdc) 13.0 Vdc 14.0 Vdc 14.5 - 15.0 Vdc 15.0 - 16.0 Vdc
Low battery voltage (battery voltage +24 Vdc) 22.0 Vdc 20.0 Vdc 21.0 - 24.0 Vdc 17.0 - 21.0 Vdc
High battery voltage (battery voltage +24 Vdc) 26.0 Vdc 28.0 Vdc 29.0 - 30.0 Vdc 30.0 - 32.0 Vdc
         
Temperature        
Low temperature 5.0 °C 1.0 °C 5.0 - 10.0 °C 0.0 - 5.0 °C
High temperature 40.0 °C 45.0 °C 35.0 - 45.0 °C 45.0 - 50.0 °C
         
Auxiliary input        
NC contact   Contact open    
         
Smoke/Gas detection        
Smoke/Gas detection (Propane and Butane) in ppm 400 ppm 600 ppm    
         
Liquid sensors        
Liquid detection above mounting point (mounting point is bottom of Liquid sensor) 16 mm 156 mm    